Partners

Autonomy arrives through the people the plant already trusts.

Utilities buy from the water-equipment OEMs, SCADA and control vendors, analyzer suppliers and engineering firms they already work with. Hydrira's distribution thesis is to ship through them: dosing, aeration, membrane and analyzer vendors shipping Hydrira-ready autonomy, and engineering firms carrying it into their utility clients.

Four partner kindsOEM, SCADA and engineering channelsDesign partners first

run_scn_0418 · agent graph · scenario 10 nodes · 1 approval gate
01 · intake_screen Read influent and forecast ✓ SUCCEEDED 02 · orchestrator Rehearse the next 24 hours ✓ SUCCEEDED 03 · quality_anomaly Fuse cameras and analyzers ✓ SUCCEEDED 04 · dose_coagulate Compute the dose curve ✓ SUCCEEDED 05 · dose_coagulate Trim the coagulant setpoint ✓ SUCCEEDED 06 · aerate_bio Minimum-energy DO schedule ✓ SUCCEEDED 07 · orchestrator Blower move approved ◆ APPROVAL 08 · membrane_disinfect Flux hold and backwash timing ✓ SUCCEEDED 09 · compliance_energy Permit conformance check ✓ SUCCEEDED 10 · conformance Write the shift record ✓ SUCCEEDED

Illustrative scenario: one municipal activated-sludge wastewater plant with a membrane train, planning the next 24 hours after a rain forecast. Not a measured run.

Program

Four kinds of partner

Water-equipment OEMs

Dosing, aeration and blower, membrane and analyzer vendors shipping Hydrira-ready autonomy on their equipment, with the connectors, tags and limits declared.

SCADA and control vendors

SCADA, DCS and historian vendors whose systems stay the system of record while Hydrira reads, recommends and writes inside declared limits.

Engineering firms

Design and commissioning firms that model and build plants, using Simflo for as-run commissioning and carrying Hydrira into their utility clients.

Utilities and industrial operators

The first design partners: two to four sites with one wedge process, one number and the mandate to measure it.

Built for

Municipal drinking water Municipal wastewater Industrial water and wastewater Desalination Water reuse MBR plants

Plant types, not customers. Hydrira has no plant connected yet and is recruiting its first design partners.

Commercial

How the partnership would work

Stated as intent. No partner agreements are signed yet.

OEMs

Hydrira-ready equipment

Dosing skids, blowers and aeration controls, membrane skids and analyzers shipped with the connectors, tags and limits Hydrira needs, so a plant can start in shadow mode on day one.

SCADA and control

Tags in, shift record out

Tags, alarms and historian data read from the SCADA; shift record and report drafts written back, with the SCADA remaining the system of record and the interlocks untouched.

Engineering firms

Commission on the twin

Simflo for as-run commissioning and what-if planning, carried from the design office into the utility clients the firm already serves.

Run timeline

What a partner-delivered run looks like

Every Hydrira run is an ordered, inspectable sequence. This is run_scn_0418, an illustrative scenario: one municipal activated-sludge wastewater plant with a membrane train, planning the next 24 hours after a rain forecast. Ten steps, nine automatic, one human approval on the blower setpoint move, every action written to the shift record.

run_scn_0418 scenario · not measured SUCCEEDED
  1. 01 Read influent and forecast SUCCEEDED 1.2 s

    Intake-and-Screen · Flow, turbidity, ammonia and alkalinity at the headworks, and a 24-hour rain forecast that raises the expected influent by mid-afternoon.

  2. 02 Rehearse the next 24 hours SUCCEEDED 4 min 10 s

    Plant orchestrator · Simflo evaluates candidate dose, DO and flux plans over the 24-hour horizon and keeps the plans that hold permit margin through the surge.

  3. 03 Fuse cameras and analyzers SUCCEEDED 180 ms

    Quality-and-Anomaly · Clarifier blanket, foam and colour from the basin cameras fused with turbidity, pH, nutrient and residual analyzers into one calibrated plant state.

  4. 04 Compute the dose curve SUCCEEDED 2.4 s

    Dose-and-Coagulate · Coagulant and polymer dose ramp for the surge window under turbidity, phosphorus, sludge and chemical-cost constraints, cited to the plant's dosing SOP.

  5. 05 Trim the coagulant setpoint SUCCEEDED 0.6 s

    Dose-and-Coagulate · A bounded setpoint move inside the declared rate and magnitude limits for the dosing pump, with the rollback value recorded first.

  6. 06 Minimum-energy DO schedule SUCCEEDED 3.1 s

    Aerate-and-Bio · Blower and DO setpoint schedule across the basins that meets the nitrogen and phosphorus targets at the lowest kilowatt-hours the biological state allows.

  7. 07 Blower move approved APPROVAL 6 min 02 s

    Plant orchestrator · The DO setpoint change is above the plant's threshold for this loop. The process engineer on shift reviews the predicted nutrient margin and approves.

  8. 08 Flux hold and backwash timing SUCCEEDED 1.8 s

    Membrane-and-Disinfect · Flux held through the surge and the next backwash moved earlier, inside the integrity envelope; the disinfection residual minimum is untouched.

  9. 09 Permit conformance check SUCCEEDED 0.9 s

    Compliance-and-Energy · Every planned setpoint checked against the discharge permit, the nutrient limits and the residual minimum, with excursion risk forecast for the horizon.

  10. 10 Write the shift record SUCCEEDED 0.3 s

    Quality-and-Conformance · Inputs, model versions, predictions, limits, the approval and every write appended to the immutable shift record the plant owns.

Fit

Who this works for

A good partner

  • Sells into utilities and industrial water operators with $50M to $10B+ operating scope
  • Owns a stage of the treatment train or the data about it
  • Has customers asking for energy, chemical, compliance or reliability outcomes, not dashboards
  • Will co-develop connectors with a design partner

Not yet

  • Resellers looking for a finished product to list this quarter
  • Integrators expecting a certification program; none exists yet
  • Anyone who needs customer references before the first pilot has run
Accelerated computing

Physical AI, at the plant edge

A treatment plant runs around the clock on variable influent, and many utilities keep plant data on site, so perception and control inference run at the plant edge. Hydrira keeps training, simulation and optimization in the cloud, in a private cloud or on-prem. Items marked planned are on the roadmap, not running.

Jetson Orin / Thor · TensorRT · DeepStream · Holoscan

Plant-edge inference

TensorRT-optimized time-series and vision models at the plant edge; DeepStream pipelines for clarifier, basin and filter cameras; Holoscan fusing camera streams with turbidity, pH, chlorine and nutrient analyzers at 1 to 10 Hz. Jetson Thor is planned.

Triton · NIM · NVIDIA AI Enterprise

Model serving

Water-quality forecasting, anomaly detection, control recommendation and compliance retrieval served with per-tenant routing, model versioning and an audit id on every call. Self-hosted for utility on-prem and edge deployment. Planned.

DGX / HGX · NeMo

Training and fine-tuning

Time-series transformers, vision models and NeMo-tuned process and compliance reasoning trained on plant telemetry, operator corrections, images, alarms, lab results, permits and SOPs. Design target: weekly fine-tuning per design-partner cohort, then monthly fleet refreshes. Planned.

Omniverse · OVX · Modulus

The as-run twin

Simflo runs plant hydraulics, clarifier and filtration behaviour, membrane fouling, oxygen transfer and biological response as a GPU simulation calibrated to the live plant, with Modulus surrogates for fast evaluation. Planned.

Cosmos · Omniverse Replicator

Synthetic rare events

Wet-weather surges, sensor drift, foaming, fouling, filtration breakthrough and biological upsets generated as scenario variants to stress-test autonomy and train the perception and control agents. Planned.

cuOpt

Optimization

Blower and pump scheduling, chemical dosing windows, membrane cleaning, backwash timing and fleet maintenance routes solved under energy tariff, labour, asset and permit constraints.

RAPIDS

GPU analytics

ETL over high-volume SCADA tags, lab results, membrane data, alarms and image metadata to build features and golden evaluation sets. Planned.

Isaac · Jetson

Robotics

Supervised robotic sampling routes, asset-inspection rovers and materials handling across intake, treatment and disinfection, where plant policy allows robots. Planned.

Integrations

It speaks plant, not cloud

Hydrira reads and writes through the systems already in the plant. No parallel historian, no new HMI, no rip-and-replace. Connectors are built against each design partner's stack first; long-tail integrations are out of scope for the first release.

SCADA and historians

Plant SCADA, historians, PLC and DCS interfaces

Tag reads at 1 to 10 Hz, guarded setpoint writes, interlocks untouched

Dosing and chemical skids

Coagulant, polymer, pH-adjust and disinfectant dosing controllers

Dose reads, bounded setpoint writes inside declared limits

Aeration and blowers

Blower controls, DO and ammonia-based aeration control

DO and blower reads, bounded setpoint writes after approval

Membrane skids

Membrane and RO skid PLCs, TMP, flux, conductivity, integrity monitors

Reads; flux and backwash writes inside the integrity envelope

Online analyzers

Turbidity, pH, chlorine residual, nutrient, TOC and flow analyzers

Reads; drift and fault flags

Lab and LIMS

Lab information systems, jar-test and grab-sample records

Reads for labels and calibration

Cameras and robots

Fixed cameras on clarifiers, basins, filters and membrane rooms; inspection robots

Streams fused at the edge; supervised routes

Utility MES, CMMS, permits

Utility MES, maintenance systems, permit and reporting systems, weather

Reads; shift record and report drafts written back

See all integrations

Guardrails

An agent that can move a setpoint needs a leash

Hydrira writes to control equipment in a plant that keeps a community's water safe. Every capability is scoped, every write is policy-checked, every output is cited, and every action is written to an append-only audit log the plant owns.

  • Bounded action space. Each agent can only write to an explicit tag allow-list, inside per-tag rate and magnitude limits, at the autonomy stage the plant has set.
  • Permit limits are read, never written. Permit-limit setpoints, disinfection residual minimums, integrity limits and discharge release decisions stay with the permit and the operator of record.
  • Policy engine before every write. Autonomy stage, interlock state, permit margin, excursion forecast and operator presence are evaluated before a setpoint moves.
  • Grounded and cited. Every recommendation carries a citation to the permit, SOP or regulation it relied on. Retrieval is tenant-isolated and permission-aware.
  • Immutable audit log. Append-only, exportable and retained on the plant's own storage, aligned to Safe Drinking Water Act, discharge-permit and EU Water Framework record-keeping.
  • Hard fallback. If the edge node, the network or a model stops, the plant keeps running on its existing SCADA, PLC and DCS control and interlocks.
  • Tenant isolation and critical-infrastructure posture. Telemetry, permits, SOPs and models never cross a customer boundary. On-prem and edge-only deployment available for utilities.

Assurance posture

Assurance and certification status
ItemScopeStatus
SOC 2 Type I + critical-infrastructure cyber reviewCloud control plane, edge QUEUED Roadmap, first 6 months
SOC 2 Type IICloud control plane QUEUED Roadmap, 6 to 12 months
SDWA · discharge permits · EU WFD · nutrient and PFAS rulesGrounding and record-keeping RUNNING Design basis for retrieval and the audit log
Per-tenant isolationData, memory, models RUNNING Design rule
On-prem or edge-only deploymentUtilities, critical infrastructure RUNNING Design option

Hydrira supports your compliance records. It is not a certification, it does not replace your permit and it never removes the operator of record from a compliance decision.

Read the security overview

Enterprise

Standardize autonomy across the fleet

One policy model, one audit trail and one set of energy, chemical, compliance and water-quality benchmarks across every plant in the fleet, with each site's permits, SOPs and process models kept private to that site.

Talk to us Enterprise details

  • Multi-site plant-edge fleet with shared model governance
  • Custom process, compliance and energy models per site
  • SSO and role-based access, named approvers (roadmap, 6 to 12 months)
  • Model versioning, validation reports and rollback
  • On-prem or private-cloud deployment
  • SLAs and outcome-based components on the highest-value workflows
FAQ

Straight answers

The questions operations managers, process engineers and compliance leads ask in the first meeting.

Only at the autonomy stage your plant has set, and only to an explicit allow-list of low-risk loops inside documented limits. Every design partner starts in shadow mode, where Hydrira predicts and writes nothing. Assist mode follows, where a process engineer approves each move. Bounded write-back comes last, per loop, after the accuracy gate and compliance sign-off, and can be pulled back at any time.

Get started

Bring autonomy to your customers' plants

If you sell to utilities and industrial water operators, the first conversation is about one of their processes.